Differential pressure transmitter - FKC high static pressure

Differential pressure measurement

Fields of application

The differential pressure transmitter - FKC high static pressure resists extreme conditions in the marine environment and accurately measures water, oil and gas flows in topside drilling and offshore subsea production systems.

Features

  • Extreme conditions-resistant design
  • Outstanding sensor cell performance
  • Resistance up to 1,379 bar (20,000 Psi)
  • Fuji Electric expertise and know-how
Reference: FKC-HAUTE PRESSION STATIQUE Please consult us

Specifications

 

HousingL- or T-shaped housing
Measuring ranges (kPa) [e.max.]1
6
32
130
500
3000
20000
Weight per kg (without indicator)3,1
Accuracy± 0.065% of the measurement range set as standard.
An accuracy of ±0.04% is also available as an option.
Materials in contact with the processStainless steel 316L, Hastelloy-C, Monel, Tantalue, Stainless steel 316L + Gilding, Monel coating, Tantalue coating
Case materialsLow-copper aluminum alloy with polyester coating, or 316L stainless steel
Membrane materialsStainless steel 316L
Hastelloy-C
Monel
Tantalum
Stainless steel 316L and Gilding
Gilding and Ceramics
Stability±0.1% of maximum scale for 10 years for digit
6 = 3, 5, 6, 8 and 9.
Elevation / SuppressionFrom -100 to +100% of maximum scale
Scale setting range1 to 1/100 of maximum scale
Measurement cycle40 ms
Communication protocolHARTTM 7 communication protocol
Process temperatureFrom +40° to +120°C (versions for higher temperatures are available)
Ambient temperatureFrom -40° to +85°C
Power supply10.5 to 45V DC
Output signal / Load resistance4-20 mA / 250 Ω typical
DampingConfigurable between 0.04 and 32 secs
Zero and span adjustmentVia external sensor screw, local three-button display or HARTTM protocol
Electrical connectionsM20x1.5" / 1/2 - 14 NPT / Pg13.5
OptionsDigital indicator, degreasing treatment, oxygen service, chlorine service, additional stainless steel identification plate

Documentations

Software: Windows USB/HART modem drivers for pressure transmitter FCX

Software Download

Carousel: How to obtain reliable measurements under high static pressure?

Carousel Download

Carousel: 5 factors to limit the pressure transmitters failures on your facilities

Carousel Download

Carousel: 7 steps to choose the safest pressure transmitter for your hazardous areas

Carousel Download

Carousel: 7 factors that influence the accuracy of your pressure transmitters

Carousel Download

Software: Configuration of pressure transmitter FDT DTM pack for FCX V4 V5 VG V6

Software Download

Brochure: pressure transmitters high static pressure differential 20,000 psi

Brochures Download

Brochure: pressure transmitters differential pressure for high static pressure FKC 15,000 psi

Brochures Download

Brochure : Pressure transmitters

Brochures Download

Brochure: Measures for energy and the environment

Brochures Download

Technologies

Discover similar products

Differential pressure transmitter - FKC high static pressure

Reference : FKC-HIGH STATIC PRESSURE