The differential pressure transmitter FKC is used in various applications such as level measurement, flow measurement, density measurement, filtration and interface measurement.
Features
3 and 5-valves manifold for differential pressure transmitter
From
313,00 € DiscoverFrom
11,00 € DiscoverThe FCX-AIV family of FKC pressure transmitters precisely measures differential pressure, liquid level or flow, and converts it into a directly proportional 4-20 mA output signal. At the heart of the measuring element is a micro-capacitive silicon transducer with a proven track record in the process industry. The digital signal processing carried out by the electronics unit ensures outstanding accuracy and stability. The FCX-AIV family of pressure transmitters complies with integrity and safety levels SIL 2 (HFT=0) and SIL 3 (HFT=1) in accordance with IEC 61508 and IEC 61511 standards.
Housing | L- or T-shaped housing |
Measuring ranges (kPa) [e.max.] | 1 6 32 130 500 3000 20000 |
Weight per kg (without indicator) | 3,1 |
Accuracy | ± 0.065% of the measurement range set as standard. An accuracy of ±0.04% is also available as an option. |
Materials in contact with the process | Stainless steel 316 L, Hastelloy-C, Monel, Tantalue, Stainless steel 316 L + Gilding, Monel coating, Tantalue coating |
Case materials | Low-copper aluminum alloy with polyester coating, or 316 L stainless steel |
Membrane materials | Stainless steel 316 L Hastelloy-C Monel Tantalum Stainless steel 316 L and Gilding Gilding and Ceramics |
Stability | ±0.1% of maximum scale for 10 years for digit 6 = 3, 5, 6, 8 and 9. |
Elevation / Deletion | From -100 to +100% of maximum scale |
Scale setting range | 1 to 1/100 of maximum scale |
Measurement cycle | 40 ms |
Communication protocol | HARTTM 7 communication protocol |
Process temperature | From +40° to +120°C (versions for higher temperatures are available) |
Ambient temperature | From -40° to +85 °C |
Power supply | 10.5 to 45 V DC |
Output signal / Load resistance | 4-20 mA / 250 Ω typical |
Damping | Configurable between 0.04 and 32 secs |
Zero and span adjustment | Via external sensor screw, local three-button display or HARTTM protocol |
Electrical connections | M20x1.5" / 1/2 - 14 NPT / Pg13.5 |
Options | Digital indicator, degreasing treatment, oxygen service, chlorine service, additional stainless steel identification plate |
Carousel: Do hot and extreme temperatures in your processes challenge your pressure measurements?
Carousel DownloadCarousel: 5 factors to limit the pressure transmitters failures on your facilities
Carousel DownloadCarousel: 7 steps to choose the safest pressure transmitter for your hazardous areas
Carousel DownloadFlyer: Increase production efficiency with FCX primary element and pressure transmitter
Flyer DownloadFlyer : Supply, commissioning and maintenance made simple for FCX smart pressure transmitter
Flyer DownloadFrom
5049,00 € DiscoverDifferential pressure transmitter - FKC
Reference : FKC
Configure