Variable frequency drive for pump and fan
Field of application
Fans, electric pumps
Features
The variable frequency drive for pump and fan - FRENIC-ACE-H E2H offers optimum energy-saving capabilities for HVAC and water pump applications. Its user-friendliness, network compatibility and long-term reliability all contribute to sustainable system performance. What's more, its customized logic enables the variable frequency drive FRENIC-ACE-H E2H to tailor its functionality to the specific requirements of each application.
Fields of application | Fans | Extractor fan Air handling unit Compressor Air conditioning system Dryer Boiler fan Oven temperature control fan Roof-mounted fan Refrigerator Fan incorporated in film manufacturing machines Cooling tower fan Ventilation fan Fan diaphragm seal | |
Electric pumps | Cooler Potable water supply system Tankless water supply system Submersible motor pump Vacuum pump Fountain pump Cooling water pump Hot water circulation pump Well pump Agricultural storage pump Water treatment systems Constant flow pump | ||
Input | Phases, Voltage, Frequency | Three-phase 400 VAC | 380 to 480 VAC, 50/60 Hz |
Three-phase 200 VAC | 200 to 240 VAC, 50/60 Hz | ||
Single-phase | 200 to 240 VAC, 50/60 Hz | ||
Variations | Voltage: +10 to -15% (voltage unbalance: 2% or less) Frequency: +5 to -5 | ||
Overload capacity | 150% of rated current for 1 min (HDD) (HD), 120% of rated current for 1 min (ND) (HND), 200% of rated current for 3 seconds (HHD) | ||
Output frequency | Maximum frequency | HHD/HND/HD mode: Variable from 25 to 500 Hz under U/F control, vector control without magnetic head position sensor // up to 200 Hz under vector control vector control with speed sensor // ND mode: 25 to 120 Hz (regardless of control) | |
Base frequency | Variable from 25 to 500 Hz (in conjunction with max. frequency) | ||
Rated frequency | Variable from 0.1 to 60.0 Hz | ||
Switching frequency | Three-phase 200 VAC: FRN0030/0040/0056/0069Eo-2o: Variable from 0.75 to 16 kHz (HHD/HND mode) // Three-phase 400 VAC: FRN0022/0029/0037/0044/ 00592oS-4o : Variable from 0.75 to 16 kHz (HHD/HND/HD mode), Variable from 0.75 to 10 kHz (ND mode) // FRN0072/0085/0105/0139/0168E2o-4o: Variable from 0.75 to 16 kHz (HHD mode), Variable from 0.75 to 10 kHz (HND/ HD mode), Variable from 0.75 to 6 kHz (ND mode) // FRN0203E2o-4o or higher : Variable from 0.75 to 10 kHz (HHD mode), Variable from 0.75 to 6 kHz (HND/HD/ND mode) | ||
Control method | Asynchronous motor control: U/F control, U/F control without speed sensor speed sensor (Dynamic Torque Vector Control), U/F control, with slip slip compensation Synchronous motors: Vector control without magnetic head position sensor | ||
Acceleration time / Deceleration time | 0 to 3600 s | ||
Multi-speed frequency | 16 speeds | ||
Frequency control (analog input) | Terminal [12]: 0 to ±10 VDC (±5 VDC)/ 0 to ±100%, 0 to +10 VDC (+5 VDC)/ 0 to +100% // Terminal [C1] function C1: 4 to 20 mACC/ 0 to +100% / 0 to ±100%, 0 to 20 mACC/ 0 to +100% / 0 to ±100% // Terminal [C1] function V2: 0 to +10 VDC(+5 VDC)/ 0 to +100%/ 0 to ±100%, inverted mode available (20 to 4; 20 to 0) | ||
Degree of protection | IP20 closed type, UL open type (22 kW or less), IP00 open type, UL open type (30 kW or more) | ||
Compliance | CE Directive (CE marking), UL Standard (cUL certification) EAC, ST0 |
Manual: Appendix H before using the FRENIC-ACE-H E2H pump and fan frequency inverter
Manuals DownloadVariable frequency drive for pump and fan - FRENIC-ACE-H E2H
Reference : FRENIC-ACE-H E2H