Based on proven inductive electrification technology, the ZiDM series has a detection limit of 0.01 mg/m³ and retains its world-renowned reliability and robustness.
The various functions available mean that the ZiDM series can be used for a wide variety of applications: emission measurement, industrial process control or filtration system monitoring.
It can be installed into process applications like baghouse, cyclone, dryer or other dust collection systems to monitor particulate emissions as well as filter performance.
The ZiDM series is often used for process control in applications where dust levels must not exceed defined limits. The integrated relays of the ZiDM series can be used as alarm signals for dust levels.
The mA output and the RS485 interface make the instrument ideal for trend monitoring applications.
Very short response time is a typical characteristic of Fuji Electric dust monitors, enabling early detection of malfunctions in the dust removal process and prevention of expensive product loss to the environment.
Δ = Standard - = Option | ZiDM-3 MONIDUST | ZiDM-4 EMIDUST | ZiDM-5 QALDUST |
Rugged IP66 rated Aluminum pressure casted enclosure | Δ | Δ | Δ |
Quick clamp process connection for easy installation | Δ | Δ | Δ |
Green, yellow and red LED for status indication | Δ | Δ | Δ |
Auto Setup function for basic setup | Δ | Δ | Δ |
Two dry contact relays to indicate dust alert and dust alarm | Δ | Δ | Δ |
The instrument can be powered with 24 V DC or 100 to 240 V AC | Δ | Δ | Δ |
USB interface for convenient connection during commissioning | Δ | Δ | Δ |
DustTool PC-software for parametrization and setup | Δ | Δ | Δ |
Normalized during production to ensure identical instruments and quality | Δ | Δ | Δ |
Linearized during production to standard test dust (Arizona Road Dust) | Δ | Δ | Δ |
RS485 to communicate with Modbus RTU or Fuji Electric protocol | Δ | Δ | Δ |
Bright green illuminated 4- digit display and buttons for local setup and status | Δ | Δ | Δ |
Isolated and active mA-output, with NAMURNE43 compliant alarms | Δ | Δ | Δ |
Zero & span check with automatic drift compensation | Δ | Δ | Δ |
Calibration possibility to read directly mg/m3 | - | Δ | Δ |
QAL1 certified by TÜV and MCERTS according to EN14181:2014 | - | - | Δ |
Flow speed compensation by the mA-output of a third party measurement device | - | Δ | Δ |
Wireless Network capability to avoid cabling cost and extensive installation | - | - | - |
The measurement is based on particles interacting with an isolated probe mounted into a duct or stack. When moving particles pass nearby or hit the probe, a signal is induced. This signal is then processed through a series of advanced algorithms to filter out the noise and provides the most accurate dust measurement.
Classic triboelectric technology is based on the DC signal, which is caused by particles making contact with the sensor to transfer charges.
Inductive Electrification Technology is based on the Triboelectric AC signal and it minimizes the influence of sensor contamination, temperature drift and velocity changes. By using Inductive Electrification Technology, it is possible to reach a detection limit as low as 0.01 mg/m³.
The Auto Setup function is a unique Fuji Electric Dust Monitor feature which allows for a simple, user friendly setup. During the Auto Setup procedure, which is done in normal process conditions, the dust monitor will automatically adapt to the process conditions and set the measuring range and alarms accordingly. At normal conditions the instrument will show green light and the mA output is set to 5% of range.
In case the measuring point is before the filtration system, the Auto Setup baseline could be several g/m³ and after the filtration system the Auto Setup baseline could be only a few mg/m³. In both cases, no manual range setup is required.
The analysers ZiDM-4 EMIDUST and ZiDM-3 MONIDUST are equipped with a local user interface for configuration and adjustment.
The operator can view measurement values in real time on the 4-digit display, in mA, % or mg/m³.
The 4-button interface allows the operator to navigate through the menus and modify the most important parameters.
An additional button to start the automatic configuration procedure is located next to the display.
Since 1993, our dust measurement technology has been recognized worldwide, with over 17,000 installations in more than 50 countries.
The measurement principle has become a proven standard for the accurate detection and quantification of dust levels.
Numerous laboratory test campaigns have also demonstrated excellent linearity on different types of dust.
The graph below illustrates the mA output in the ISO 12103 standard test (Arizona Road Dust Test).
Temperature tests showed close to no impact over the whole temperature range.
The ZiDM series is available with a wide range of probes and process connections.
The new mechanical solutions reflect our field of experience over the last twenty years.
The ZiDM series has been designed and developed to adapt to industrial processes and customer requirements.
The ZiDM series is supplied with a 500 mm probe made of 316L stainless steel and Ryton insulation. This probe withstands temperatures up to 300°C and pressure up to 600 kPa. The quick-release clamp enables the instrument to be removed quickly and easily. This is particularly useful in harsh process conditions, where probes need to be cleaned regularly.
Probe Lengths and Coatings (Optional):
A wide range of different probes are available as options to allow customized solutions. Adhesive and wet dusts may create a conductive dust build up on the probe which will negatively influence on the monitor’s accuracy and reliability.
As Inductive Electrification is based on the transfer of electrostatic load from the probe to the amplifier, conductive dust build up may lead to a bridging effect from the probe to the grounded ductwork.
To help avoid this bridging, Fuji Electric has developed a number of coatings for the different process conditions:
Used in process conditions with high probability of dust build up on the probe.
Air purge ensures that the base of the probe stays clean of dust build up.
The high-temperature probe can be used in process conditions up to 700°C.
The air purge option is not available for this sensor.
Flanges for process connection can be selected according to the customer's datasheet .
The analysers ZiDM series can be networked using a Fuji Electric RF platform.
This reduces cabling costs and eases installation with a fully integrated, easy to use RF connection.
Each monitor has a range of up to 1 km and can act as a repeater within the network. With directional antennas the range can be significantly extended.
Wireless network features :
The analysers ZiDM series can be managed and parameterized with DustTool software. This provides a convenient platform for viewing measurement results, initiating auto-tuning and adjustinganalyser parameters.
Plug a USB cable directly into the USB connector, or use a generic USB-RS485 converter, then simply connect to the unit's RS485 bus.
DustTool will automatically detect the interface being used and connect to the device.
ZiDM-5 QALDUST is approved for plants subject to the following regulations:
0 ... 7.5 mg/m³
0 ... 15 mg/m³
0 ... 100 mg/m³
QALDUST's QAL1-certified ZiDM-5 dustmeteranalyser is a must-have instrument for accurate monitoring of total suspended particulates (TSP). Equipped with state-of-the-art technology, this analyser offers outstanding performance in a wide range of operating conditions.
Measurement principles and measurement objects:
This dust monitor is based on the principle of inductive electrification, guaranteeing high accuracy in the measurement of suspended particles.
Measurement Scale and Certification Range:
Extended measuring range and different certification ranges ensure flexible adaptation to different operating environments.
Protection class and power supply:
The high protection rating (IP66) ensures the analyser's reliability in harsh environmental conditions, while power supply options offer installation flexibility.
Output signals and communication:
A wide range of output signals and communication interfaces facilitates integration with other systems and enables remote monitoring.
Case and Materials:
Sturdy aluminum construction and the use of high-quality materials guarantee enhanced durability in demanding environments.
Environmental conditions and performance:
These features ensure optimum performance over a wide range of environmental and operating conditions.
Wireless communication:
Wireless communication offers greater flexibility with extended range, facilitating remote monitoring.
This example calculation shows the payback period and cash flow over 3 years based on the loss of product which is caused by a small leakage in the filtration system.
This means: Lost product: 84 000 kg/year, probably released to the environment. More than 20 000 € savings after 3 years and a payback time of less than 3 months.
The analysers dust monitors ZiDM-3 MONIDUST and ZiDM-4 EMIDUST are advanced instruments designed for accurate monitoring of total suspended particulates (TSP). Featuring state-of-the-art inductive electrification technology, these instruments offer exceptional reliability in a variety of operating conditions.
Measurement principles and measurement objects:
The inductive electrification principle guarantees accurate and reliable measurement of suspended particles, providing a robust solution for air quality monitoring.
Scale of Measurement and Protection Index:
With an extended measuring range and IP66 protection, these analysers units are ready to cope with a wide range of environments, even under harsh conditions.
Power supply and consumption:
With flexible power supply, these analysers can be efficiently integrated into various systems, offering versatile installation options.
Output signals and communication:
A variety of output signals and communication options enable easy integration with existing monitoring systems.
Case and Materials:
Robust aluminum construction and the use of high-quality materials ensure exceptional durability in demanding environments.
Environmental conditions and performance:
These features enable use in a wide range of environmental conditions, while ensuring optimum performance.
Wireless communication:
Wireless communication offers extended range, facilitating remote surveillance in a variety of urban environments.